YY-Electron Wireless Home Security Alarm System Instrukcja Obsługi Strona 27

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 32
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 26
Wired
Detectors
27
This device is designed to detect the presence
of fire inside residential or commercial buil-
dings. The detector has a built-in local warning
siren with an optical memory of the alarm. It
combines an optical smoke sensor with a heat
sensor which can react to the inadequate rise
of the temperature in the room. The detector
has selectable alarm triggering conditions
(smoke or heat, smoke only, heat only, smoke
and heat). The SD-401 is the stand-alone ver-
sion powered by a 1.5V AA alkaline battery.
Voltage 9 - 15 V DC
Smoke detection optical, light dispersion
Smoke sensor sensitivity m = 0.11 - 0.13 dB/m
pursuant to EN 14 604
Temperature detection A2 class pursuant to EN 54-5
Fire-alarm temperature +60 °C to + 70 °C
Low battery signalization optical
Acoustic signalling min. 85 dB/3 m
Dimensions 126 mm, heigh 65 mm
Complies with EN 14 604, A2 EN 54-5,
EN 50130-4, EN 55022
Wired Detectors
The detector indicates leaks of all kinds of com-
bustible gases (such as Natural Gas, Lighting
Gas, Propane, Butane, Acetylene, Hydrogen etc.)
and reacts by signaling two levels of gas con-
centration. It is powered by 12 V DC. High
stability, sensitivity and a long lifetime are
the characteristic features of the detector. The
apparatus indicates the gas leak acoustically
and optically. It is also equipped with an output
relay with selectable functions. The GS-130
detector is a mains-powered version (230 V AC).
Voltage (GS-133) 12 V DC
Voltage (GS-130) 230 V/50 Hz, 5 W consumption
Sensitivity 1
st
level 10% LEL; 2
nd
level 20% LEL
LEL LEL = Lower Explosive Limit
Buzzer sound level 94 dB/0.3 m
Relay output triggering at 1
st
or 2
nd
LEL level,
max. 230 V/5 A
Detection method hot fiber (catalytic combustion)
Enclosure protection IP 30 (EN 60 529)
Dimensions 100 x 73 x 39 mm
GS-133 / GS-130 Gas-Leak Detectors
SD-280 Optical Fire Detector
SA-200A Magnetic contact with terminal unit, dimensions 49 x 14 x 13 mm.
SA-204 Surface metal contact for industrial applications and also metal doors, wired, 49 x 17 x 9 mm,
working distance max. 40 mm.
SA-210 Stud contact with terminal unit, 10 mm, magnet length 15 mm, relay 23 mm, white design.
SA-211 Stud mini contact with extra shallow cable 9 mm, magnet length 3 mm, relay 14 mm,
working distance max. 19 mm, white design.
Magnetic Detectors
SA-204
SA-210
SA-211
SA-200A
The detector works as an indicator of a room
being flooded by water (e.g. cellars, bathrooms).
This information is sent to an alarm system to
send out an alert message. The LD-81 is con-
nectible to an Oasis alarm system via a JA-81M
wireless detector and to a PROFI system via a JA-60N. The LD-81 detector does not need any power as it takes
its power supply from the JA-81M´s circuit. The LD-12 detector is powered by 12 V and offers NO/NC output.
Operating environment II. General indoor,
-10 to +40 °C, EN 50130-4, EN 55022
Enclosure protection IP 68
Power supply LD-12 12 V DC ± 15 %; 2 mA
Dimensions 53 x 20 x 10 mm
LD-81 / LD-12 Flood Detector